2-962
Catalyst 6500 Series Switch Command Reference—Release8.4
OL-6244-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands
show mls cef interface
This example show how to display information for a specific CEF VLAN:
Console> (enable) show mls cef interface 46
Module 16: vlan 46, IP Address 46.0.0.99, Netmask 255.0.0.0
MTU = 1500, State = up, ICMP-Unreach = enabled, ICMP-Redirect = enabled
Unicast RPF = disabled
Console> (enable)
Table 2-50 describes the possible fields in the show mls cef interface command output.
Related Commands clear mls cef
show mls cef mac
show mls cef summary
show mls entry cef
Table2-50 show mls cef interface Command Output Fields
Field Description
Vlan VLAN associated with the interface.
IP Address IP address associated with the interface.
Netmask IP network mask associated with the interface.
MTU IP MTU associated with the interface.
State Interface state (up or down).
ICMP-Unreach Status of whether denied Layer 3 packets will be bridged to
MSFC to generate ICMP unreachable.
ICMP-Redirect Status of whether Layer 3 packets whose destination VLAN is
equal to the source VLAN should be redirected to the MSFC to
generate ICMP redirect.
Unicast RPF Unicast RPF enable/disable.