2-762
Catalyst 6500 Series Switch Command Reference—Release8.4
OL-6244-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands
set test diagfail-action
set test diagfail-action
To set the action that the supervisor engine takes when a diagnostics test fails, use the set test
diagfail-action command.
set test diagfail-action {offline | ignore}
Syntax Description
Defaults The supervisor engine stays offline.
Command Types Switch command.
Command Modes Privileged.
Usage Guidelines Enter the show test diagfail-action command to display the action that the supervisor engine takes after
a test failure.
Examples This example shows how to set the supervisor engine to stay offline:
Console> (enable) set test diagfail-action offline
Diagnostic failure action for SUP set to offline.
Console> (enable)
This example shows how to set the supervisor engine to ignore the diagnostics test failure and to boot up:
Console> (enable) set test diagfail-action ignore
Diagnostic failure action for SUP set to ignore.
Console> (enable)
Related Commands show test
offline Sets the supervisor engine to stay offline after a diagnostics test failure.
ignore Sets the supervisor engine to ignore the diagnostics test failure and to b oot up.