2-1268
Catalyst 6500 Series Switch Command Reference—Release8.4
OL-6244-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands
show system sanity
show system sanity
To display the output for the sanity checks that the system has performed, use the show system sanity
command.
show system sanity
Syntax Description This command has not arguments or keywords.
Defaults This command has no default settings.
Command Types Switch command.
Command Modes Privileged.
Usage Guidelines The show system sanity command runs a series of checks on your configuration and highlights possible
conditions that could lead to problems with your configuration.
Examples This example shows how to display the output for sanity checks:
Console> (enable) show system sanity
Status of the default gateway is:
172.20.52.1 is alive
Please check your confreg value : 0x10f.
Invalid boot image slot0:cat6000-sup2k8.8-3-0-133-BOC.bin specified in the bootstring.
Please check your boot string.
Invalid boot image bootflash:cat6000-sup2k8.7-5-0-98.bin specified in the boot string.
Please check your boot string.
None of the images specified in the boot string are valid.
Please specify at least one valid image in the boot string to ensure the switch
is in a bootable state.
The value for Community-Access on read-only operations for SNMP is the same as default.
Please verify that this is the best value from a security point of view.
The value for Community-Access on read-write operations for SNMP is the same as
default.
Please verify that this is the best value from a security point of view.
The value for Community-Access on read-write-all operations for SNMP is the same
as default.
Please verify that this is the best value from a security point of view.
UDLD has been disabled globally - port-level UDLD sanity checks are being bypassed.
The following ports have receive flowControl disabled:
3/1,3/48