2-804
Catalyst 6500 Series Switch Command Reference—Release8.4
OL-6244-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands
show autoshut
show autoshut
To display the automatic module shutdown configuration and current status information, use the
show autoshut command.
show autoshut
Syntax Description This command has no arguments or keywords.
Defaults This command has no default settings.
Command Types Switch command.
Command Modes Normal.
Usage Guidelines The run-time variable states for Ethernet modules do not synchronize with the standby supervisor
engine. The output of the show autoshut command on a standby supervisor engine does not track with
the number of resets or the reasons for the resets. If the mo dule is powered d own by th e set autoshut
command, the output stays the same.
Examples This example shows how to display the automatic module shutdown configuration and current status
information:
Console> show autoshut
AutoShut Frequency: 3 times
AutoShut Period: 5 minutes
Mod Autoshut Current Number Reason for last Time of last reset
num status status resets reset
--- -------- -------- ------ ---------------- -------------------------
1 NA ok - - -
2 enabled shutdown 4 inband failure Mon Jul 14 2003, 22:55:45
3 disabled ok 0 None -
4 enabled ok 1 scp failure Mon Jul 14 2003, 21:03:17
Console>
Related Commands clear autoshut
set autoshut
set module autoshut