2-872
Catalyst 6500 Series Switch Command Reference—Release8.4
OL-6244-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands
show environment
Related Commands set inlinepower
show port inlinepower
Slot power Requirement/Usage
Power Requested Module power requested.
Power Allocated Module power allocation.
Card Status Module status (no, ok, partial-deny2, unknown, power-bad, and
power-deny).
Slot Inline Power Requirement/Usage
Total Allocated to Module Inline power in Watts already allocated to the specified module.
Max H/W Supported Per Module Maximum hardware supported per module in Watts.
Max H/W Supported Per Port Maximum hardware supported per port in Watts.
Total inline power drawn Total inline power drawn from the system.
InlinePowered—Admin Inline power management status—auto, on, and off.
InlinePowered—Oper Inline power status—on indicates power is being supplied by that port, off
indicates power is not being supplied by the port, denied indicates there is
not have enough power available to provide to the port.
InlinePowered—Detected Status of whether or not inline power is detected.
1. Environmental status indications are the following: . = Pass, F = Fail, U = Unknown, and N = Not Present.
2. The partial-deny state indicates that some ports but not all ports in the module are inline powered.
Table2-32 show environment Command Output Fields (continued)
Field Description