2-402
Catalyst 6500 Series Switch Command Reference—Release8.4
OL-6244-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands
set logging session
set logging session
To enable or disable the sending of system logging messages to the current login session, use the set
logging session command.
set logging session {enable | disable}
Syntax Description
Defaults The default is system message logging to the current login session is enabled.
Command Types Switch command.
Command Modes Privileged.
Examples This example shows how to prevent system logging messages from being sent to the cur re nt log in
session:
Console> (enable) set logging session disable
System logging messages will not be sent to the current login session.
Console> (enable)
This example shows how to cause system logging messages to be sent to the curre nt lo gin sess ion:
Console> (enable) set logging session enable
System logging messages will be sent to the current login session.
Console> (enable)
Related Commands set logging console
set logging level
show logging
show logging buffer
enable Enables the sending of system logging messages to the current login session.
disable Disables the sending of system logging messages to the current login session.