2-1278
Catalyst 6500 Series Switch Command Reference—Release8.4
OL-6244-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands
show test
This example shows the display if you do not specify a module:
Console> show test
Environmental Status (. = Pass, F = Fail, U = Unknown, N = Not Present)
PS1:. PS2:N PS1 Fan:. PS2 Fan:N
Chassis-Ser-EEPROM:. Fan:.
Clock(A/B):A Clock A:. Clock B:.
VTT1:. VTT2:. VTT3:.
Module 1 :2-port 1000BaseX Supervisor
Network Management Processor (NMP) Status:(. = Pass, F = Fail, U =
Unknown)
ROM: . Flash-EEPROM:. Ser-EEPROM:. NVRAM:. EOBC Comm:.
Line Card Firmware Status for Module 1 :PASS
Port Status :
Ports 1 2
-----------
. .
Line Card Diag Status for Module 1 (. = Pass, F = Fail, N = N/A)
Module 1
Earl IV Status :
NewLearnTest: .
IndexLearnTest: .
DontForwardTest: .
DontLearnTest: .
ConditionalLearnTest: .
BadBpduTest: .
TrapTest: .
MatchTest: .
SpanTest: .
CaptureTest: .
Loopback Status [Reported by Module 1] :
Ports 1 2
-----------
. .
Channel Status :
Ports 1 2
-----------
. .
This example shows how to display diagnostic level status:
Console> show test diaglevel
Diagnostic mode at last bootup : minimal
Diagnostic mode at next reset : bypass
Console>
This example shows how to display the action that the supervisor engine takes after a diagnostics test failure:
Console> show test diagfail-action
Diagnostic failure action for SUP at last bootup : offline
Diagnostic failure action for SUP at next reset : ignore