2-313
Catalyst 6500 Series Switch Command Reference—Release8.4
OL-6244-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands set errdisable-timeout
set errdisable-timeout
To configure a timeout to automatically reenable ports that are in the errdisable state, use the set
errdisable-timeout command.
set errdisable-timeout {enable | disable} {reason}
set errdisable-timeout interval {interval}
Syntax Description
Defaults By default, all the errdisable state reasons are disabled globally; whenever ther e are no reas ons enabled,
the timer is stopped.
By default, the timeout is set to disable, and the interval value is set at 300 seconds.
Command Types Switch command.
Command Modes Privileged.
Usage Guidelines A port enters errdisable state for the following reasons (these reasons appear as configuration options
within the set errdisable-timeout enable command):
rp-inspection—ARP inspection
bcast-suppression —Broadcast suppression
bpdu-guard—BPDU port-guard
cam-monitor—CAM monitoring
channel-misconfig—Channel misconfiguration
crossbar-fallback—Crossbar failure
duplex-mismatch—Duplex mismatch
gl2pt-ingress-loop—Layer 2 protocol tunnel misconfiguration
gl2pt-threshold-exceed—When Layer 2 protocol tunnel threshold is exceeded
gl2pt-cdp-threshold-exceed—When Layer 2 protocol tunnel CDP threshold is exceeded
enable Enables errdisable timeout.
disable Disables errdisable timeout.
reason Reason for the port being in errdisable state; valid values are arp-inspection,
bcast-suppression, bpdu-guard, channel-misconfig, cross-fallback,
duplex-mismatch, gl2pt-ingress-loop, gl2pt-threshold-exceed,
gl2pt-cdp-threshold-exceed, gl2pt-stp-threshold-exceed,
gl2pt-vtp-threshold-exceed, link-rxcrc, link-txcrc, udld, other, all.
interval
interval Specifies the timeout interval; valid values are from 30 to 86400 seconds (30 seconds to
24 hours).