Siemens 400 V / 210...590 A Profile parameters, P927 Parameter Access, P928 Src Base/Reserve

Models: 400 V / 210...590 A

1 166
Download 166 pages 35.09 Kb
Page 105
Image 105

01.2004

Parameter List

 

 

12.14Profile parameters

 

PNU

 

Parameter Name in OP1

 

 

Range

# of Indices

read:

_/_

 

 

 

 

 

 

 

[Unit]

Factory

write:

_/_

 

*:conf-P

 

Description

 

 

Value Texts

Settings

 

 

 

 

P918

 

CB Bus Address

 

 

0 to 200

3 / H BR

 

396Hex

 

Protocol-dependent bus address for communication boards: see

 

3

3 / H

 

 

 

board documentation

 

 

 

 

 

 

 

 

 

 

Note:

The validity of the bus address is monitored by the

 

 

 

 

 

 

 

 

 

Com Board. If its value is not accepted by COM

 

 

 

 

 

 

 

 

 

BOARD, fault F080 with fault value 5 is displayed

 

 

 

 

 

 

 

 

Precondition: P090 = 1 or P091 = 1 (Communication board

 

 

 

 

 

 

 

 

logged on)

 

 

 

 

 

 

 

 

 

 

 

Type=O2;

PKW: 1HEX=1.0

PZD Gr.: -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P927

 

Parameter Access

 

 

0 to 31

3 /

BR

 

 

*

 

Enabling of interfaces for parameterization

 

 

6

3 /

BR

 

 

39FHex

 

See P053 for description.

 

 

 

 

 

 

 

 

 

 

Type=O2;

PKW: 1HEX=1.0

PZD Gr.: -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P928

 

Src Base/Reserve

 

 

0 to 5001

3 /

BR

 

 

*

 

Source for basic/reserve setting switchover command (control

 

1005

3 /

BR

 

 

3A0Hex

 

word 2, bit 30); this parameter is identical to P590.

 

 

 

 

 

 

 

 

 

See P590 for description.

 

 

 

 

 

 

 

 

 

 

Type=L2; PKW: PKW format(HEX)=param.value

PZD Gr.: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Siemens AG 6SE7087-6CX86-2BA1

12-35

SIMOVERT MASTERDRIVES AFE Operating Instructions

Page 105
Image 105
Siemens 400 V / 210...590 A operating instructions Profile parameters, P927 Parameter Access, P928 Src Base/Reserve