Siemens 400 V / 210...590 A operating instructions Fan, flow rate, opening cross- sections, Mlfb

Models: 400 V / 210...590 A

1 166
Download 166 pages 35.09 Kb
Page 29
Image 29

01.2004

Installation

 

 

Fan, flow rate, opening cross- sections

MLFB

 

6SE7035-1TJ80

 

 

 

6SE7036-0TJ80

 

Fan

 

2 x RH28M

 

 

 

 

Minimum flow rate [m3/s]

0.46

 

 

 

 

Min. opening cross-section in cabinet

 

 

doors [m2]

 

0.26

 

Degree of protection IP00 to IP42

 

 

Min. opening cross-section in top

 

 

plate [m2]

 

0.26

 

Degree of protection < IP20

 

 

Min. opening cross-section in top

 

 

cover [m2]

 

0.26

 

Degree of protection IP22 to IP42

 

 

Table 5-2

Fan, flow rate, opening cross-sections

Opening crss-sections in

 

Direct partition

top plate at top (also

 

between fan box and

possible at the front and/

cabinet frame from all

or at the side

 

4 sides

Cabinet frame

Partition on the left

and right of and behind adjacent cabinets

Opening cross-

sections in the doors

(with dirt filters

maybe behind them)

Fig. 5-8

Partitioning

Siemens AG 6SE7087-6CX86-2BA1

5-11

SIMOVERT MASTERDRIVES AFE Operating Instructions

Page 29
Image 29
Siemens 400 V / 210...590 A operating instructions Fan, flow rate, opening cross- sections, Mlfb