Siemens 400 V / 210...590 A operating instructions Hardware configuration, P091 Board Position

Models: 400 V / 210...590 A

1 166
Download 166 pages 35.09 Kb
Page 78
Image 78

Parameter List

01.2004

 

 

12.4Hardware configuration

PNU

Parameter Name in OP1

 

 

Range

# of Indices

read:

_/_

 

 

 

 

 

[Unit]

Factory

write:

_/_

*:conf-P

Description

 

 

 

Value Texts

Settings

 

 

P090

Board Position 2

 

 

0 to 4

3 / H BR

*

PCB in slot #2 (right) of the electronics box

 

 

0

3 / H

 

5AHex

Parameter values:

 

 

 

 

 

 

 

0 = No option board

 

 

None

 

 

 

 

1 = Communication Board (CB)

 

CB

 

 

 

 

2 = Technology Board (TB)

 

 

TB

 

 

 

 

3 = Serial Communication Board (SCB)

 

SCB

 

 

 

 

4 = Digital Tacho and Synchronization Board (TSY)

TSY

 

 

 

 

Setting instruction:

 

 

 

 

 

 

 

The following are the only permissible board/slot

 

 

 

 

 

combinations:

 

 

 

 

 

 

 

 

Slot 3 (P091)

Slot 2 (P090)

 

 

 

 

 

 

-

 

CB

 

 

 

 

 

 

-

 

TB

 

 

 

 

 

 

-

 

SCB

 

 

 

 

 

 

-

 

TSY

 

 

 

 

 

 

SCB

 

CB

 

 

 

 

 

 

CB

 

TB

 

 

 

 

 

 

SCB

 

TB

 

 

 

 

 

 

CB

 

SCB

 

 

 

 

 

 

CB

 

TSY

 

 

 

 

 

 

TSY

 

CB

 

 

 

 

 

 

SCB

 

TSY

 

 

 

 

 

 

TSY

 

SCB

 

 

 

 

 

 

Type=O2;

PKW: 1HEX=1.0

PZD Gr.: -

 

 

 

 

 

 

 

 

 

 

 

P091

Board Position 3

 

 

0 to 4

3 / H BR

*

Board in slot 3 (centre) in electronics box

 

 

0

3 / H

 

5BHex

For description, see P090 (board position 2).

 

 

 

 

 

 

Type=O2;

PKW: 1HEX=1.0

PZD Gr.: -

 

 

 

 

12-8

6SE7087-6CX86-2BA1 Siemens AG

Operating Instructions SIMOVERT MASTERDRIVES AFE

Page 78
Image 78