01.2004

 

 

 

 

 

 

 

 

 

Parameter List

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PNU

 

 

Parameter Name in OP1

 

 

Range

 

# of Indices

read:

_/_

 

 

 

 

 

 

 

 

 

 

[Unit]

 

Factory

write:

_/_

 

 

*:conf-P

 

 

Description

 

 

 

Value Texts

 

Settings

 

 

 

 

 

r012

 

 

Base/Reserve

 

 

 

 

2 / BR

 

 

 

 

 

 

 

Basic/reserve settings of the process data connections for

 

 

 

 

 

 

 

 

CHex

 

 

setpoints and control word bits

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter values:

 

 

 

 

 

 

 

 

 

 

 

 

0:

Basic setting

 

 

Basic

 

 

 

 

 

 

 

 

 

1:

Reserve setting

 

 

Reserve

 

 

 

 

 

 

 

 

 

 

Analog output: 100 % with code number (PWE) = 16384

 

 

 

 

 

 

 

 

 

 

 

Type=O2;

PKW: 1HEX=1

PZD Gr.: 0

 

 

 

 

 

 

 

 

r013

 

 

Operat. hours

 

 

 

 

3

2 / BR

 

 

 

 

 

 

 

Display of hours run with enabled inverter (in Run operating

 

 

 

 

 

 

 

 

DHex

 

 

state).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indices:

 

 

 

d

 

 

 

 

 

 

 

 

 

 

i001 = Days: Days (0...9999)

 

 

 

 

 

 

 

 

 

 

 

 

i002 = Hrs.:

Hours (0...24)

 

 

h

 

 

 

 

 

 

 

 

 

 

i003 = Sec.:

Seconds (0...3600)

 

 

s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type=O2;

PKW: 1HEX=1

PZD Gr.: 0

 

 

 

 

 

 

 

 

r030

 

 

Line volts

 

 

 

 

 

2 / BR

 

 

 

 

1EHex

 

 

Actual line voltage (fundamental r.m.s.)

 

 

[V]

 

 

 

 

 

 

 

 

 

Analog output: 100 % with code number (PWE) = 4 * P071

 

 

 

 

 

 

 

 

 

 

 

Type=O2;

PKW: 1HEX=1 V

PZD Gr.: 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

r032

 

 

Line frequency

 

 

 

 

2 / BR

 

 

 

 

20Hex

 

 

Actual frequency of line voltage

 

 

[Hz]

 

 

 

 

 

 

 

 

 

Analog output: 100 % with code number (PWE) = 163.84 Hz

 

 

 

 

 

 

 

 

 

 

 

Type=O2;

PKW: 1HEX=0.01 Hz

PZD Gr.: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Siemens AG 6SE7087-6CX86-2BA1

12-3

SIMOVERT MASTERDRIVES AFE Operating Instructions

Page 73
Image 73
Siemens 400 V / 210...590 A operating instructions 12-3, R013 Operat. hours, R030 Line volts, R032 Line frequency