4-2. Parts Replacement

4-2-24. Replacement of Tape Cleaner

m

.Tape cleaner is not installed in the product having following serial numbers and higher.

DVW-707 :

10056 and higher

DVW-707P :

40191 and higher

DVW-709WS :

10126 and higher

DVW-709WSP : 40256 and higher

DVW-790WS : 10161 and higher

DVW-790WSP : 40511 and higher

.Do not touch the edge part of the tape cleaner directly. It is very sharp and will cause injuries.

.Do not expose the tape cleaner to shock (dropping it, etc.). As it made of very hard material, its edge may break. If it has been accidentally dropped, etc., observe the edge part with a magnifying glass and check that is has not been damaged.

Overviews

Replacement

Tape Cleaner Removal

Tape Cleaner Installation

Operation Check

Preparations

1.Check the unthreading end mode.

2.Turn off the power.

3.Remove the front lid and the outside panel. (Refer to section 1-6 of Maintenance Manual Part 1.)

Tools

 

 

 

. Torque screwdriver bit (for M2)

: J-6325-380-A

. Torque screwdriver (for 3 kg)

: J-6325-400-A

 

 

 

 

Removal

 

 

M 2x5

 

 

 

1. Tape Cleaner Removal

 

 

 

Remove the screw and remove the tape cleaner.

Tape cleaner

Part A

Installation

2. Tape Cleaner Installation

(1)Press part A of the tape cleaner against part B of the CTL.FE base.

(2)Attach the tape cleaner with a screw. The standard tightening torque value :

9 x10_2 N.m {0.9 kgf.cm}

3. Operation Check

(1)Turn on the main power.

(2)While the outside panel is kept open, insert a cassette tape and enter the PLAY mode.

Part B

(3)Confirm that the tape runs while maintaining contact with the tape cleaner.

4-112

DVW-790WS/709WS/707 P2V1

DVW-790WSP/709WSP/707P P2V1

Page 196
Image 196
Sony DVW-790WS/790WSP manual Replacement of Tape Cleaner, Tape Cleaner Removal, Installation Tape Cleaner Installation