7-6 DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
7-3. AD Clock Phase Adjustment 16:9 mode
Note
Conduct this check when the CCD block or DCP-17 board
is only replaced.
Preparation
.On the setup menu, set as follows.
PAGE : S12*FUNCTON 1/2
ITEM : TEST OUT ENC
.OUTPUT/DCC switch (inside panel) CAM/ON
.WHITE BAL switch (inside panel) A
.AUTO W/B BAL switch (front panel) WHT
(Perform the automatic white balance adjustment.)
.Shoot a multiburst chart (4:3) in the underscan’s hori-
zontal picture frame.
Test point : VIDEO OUT connector
setting point : 1 Lens IRIS
Spec. : A (white level) = 90 ±2 IRE (NTSC)
A = 630 ±10 mV (PAL)
.Pan the camera so that the 5 MHz signal portion of the
multiburst chart is positioned at the center of the monitor
screen. (Do not change the camera zoom.)
Chart frame
Underscanned monitor
Frame
A
5 MHz
(Waveform monitor)
Adjustment Procedure
Equipment : Waveform monitor
Test point : VIDEO OUT connector
1. Select the 16:9 mode.
PAGE : S14*WIDE SCREEN
ITEM :16:9/4:3 MODE 16:9
2. On the setup menu, adjust as follows.
PAGE : S54*AD ADJ.
ITEM : AD CLOCK PHASE
Spec. : Maximize the 5 MHz signal portion.
3. On the setup menu, adjust as follows.
PAGE : S54*AD ADJ.
ITEM : R/B CLOCK PHASE
Spec. : Adjust the 5 MHz signal portion to
nearly horizontal.
5 MHz
NG OK
7-3. AD Clock Phase Adjustment