7-14 DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
7-9. VA Gain Adjustment 16:9 mode
Note
.Use an 89.9%-reflective chart in this adjustment as
possible. (Refer to Section 7-1-4.)
.If a “16:9” chart is not keep on hand, shoot a‘‘4:3” chart
so that the chart width is aligned with the underscanned
monitor frame.
Preparation
.OUTPUT/DCC switch (inside panel) CAM/ON
.Shoot a grayscale chart (16:9) in the full underscanned
monitor frame.
.WHITE BAL switch (inside panel) PRST
.AUTO W/B BAL switch (front panel) BLK
(Perform the automatic black balance adjustment.)
.On the setup menu, set as follows.
PAGE : S35*PRESET WHT
ITEM : COLOR TEMP <P> : 3200
ITEM : R GAIN <P> : 0
ITEM : B GAIN <P> : 0
Adjustment Procedure
1. Select the 16:9 mode.
PAGE : S14*WIDE SCREEN
ITEM : 16:9/4:3 MODE 16:9
2. Equipment : Oscilloscope
Test point : TP1 (VA-191 board)
Setting point :1 Lens IRIS
Spec. : A = 320 ±8 mV
3. On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : TEST OUT G
4. Equipment : Waveform monitor
Test point : TEST OUT connector
Adj. point : 1RV201 (VA-191 board (G GAIN))
Spec. : B = 100 ±2 IRE (NTSC)
B = 700 ±10 mV (PAL)
5. On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : TEST OUT ENC
ITEM : GAMMA OFF
6. Select portion C by using the waveform monitor.
7. Set the waveform monitor to the CHROMA mode.
8. Equipment : Waveform monitor
Test point : TEST OUT connector
Adj. point : 1RV101 (VA-191 board (R GAIN))
1RV301 (VA-191 board (B GAIN))
Spec. : Minimize carrier leakage D by using
the variable resistors alternately.
Setting After Adjustment
.On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : GAMMA ON
A
D
B
7-9. VA Gain Adjustment
C
VA-191 board (A side)
1
RV101
1
RV201
TP1
1
RV301
A
1
2
3
CB
DE