7-9. VA Gain Adjustment

7-9. VA Gain Adjustment

16:9 mode

Note

.Use an 89.9%-reflective chart in this adjustment as possible. (Refer to Section 7-1-4.)

.If a “16:9” chart is not keep on hand, shoot a‘‘4:3” chart so that the chart width is aligned with the underscanned monitor frame.

Preparation

.OUTPUT/DCC switch (inside panel) → CAM/ON

.Shoot a grayscale chart (16:9) in the full underscanned monitor frame.

.WHITE BAL switch (inside panel) → PRST

.AUTO W/B BAL switch (front panel) → BLK

(Perform the automatic black balance adjustment.)

.On the setup menu, set as follows.

PAGE

: S35*PRESET WHT

 

ITEM

: COLOR TEMP <P>

: 3200

ITEM

: R GAIN <P>

: 0

ITEM

: B GAIN <P>

: 0

 

 

Adjustment Procedure

 

1. Select the 16:9 mode.

 

PAGE

: S14*WIDE SCREEN

 

ITEM

: 16:9/4:3 MODE → 16:9

5. On the setup menu, set as follows.

PAGE

: S12*FUNCTION 1/2

ITEM

: TEST OUT → ENC

ITEM

: GAMMA → OFF

6.Select portion C by using the waveform monitor.

C

7.Set the waveform monitor to the CHROMA mode.

8. Equipment

: Waveform monitor

Test point

: TEST OUT connector

Adj. point

: 1RV101 (VA-191 board (R GAIN))

 

1RV301 (VA-191 board (B GAIN))

Spec.

: Minimize carrier leakage D by using

 

the variable resistors alternately.

D

2. Equipment

: Oscilloscope

Test point

: TP1 (VA-191 board)

Setting point : 1Lens IRIS

 

A

Spec.

: A = 320 ±8 mV

Setting After Adjustment

.On the setup menu, set as follows.

PAGE

: S12*FUNCTION 1/2

ITEM

: GAMMA → ON

3.

On the setup menu, set as follows.

 

PAGE

: S12*FUNCTION 1/2

 

ITEM

: TEST OUT → G

4.

Equipment

: Waveform monitor

 

Test point

: TEST OUT connector

 

Adj. point

: 1RV201 (VA-191 board (G GAIN))

 

Spec.

: B =

100

±2 IRE (NTSC)

 

 

B =

700

±10 mV (PAL)

 

 

 

 

 

 

B

7-14

A

1

2

3

B

1

RV301

D E

C

RV201

1

1

TP1RV101

VA-191 board (A side)

DVW-790WS/709WS/707

DVW-790WSP/709WSP/707P P2V1