5-5. CUE Head Height Adjustment

5-5. CUE Head Height Adjustment

Notes

.The CUE head height adjustment is closely related to the azimuth, zenith and position adjustments of the CUE head.

.After carrying out the CUE head height adjustment, be sure to carry out the other adjustments or checks of the CUE head.

Tools

 

. Alignment tape, ZR2-1 (NTSC)

: 8-960-073-11

. Alignment tape, ZR2-1P (PAL)

: 8-960-073-61

. TP tool

: J-6420-910-A

. Box screwdriver

 

. Oscilloscope

 

Setting

1.Turn the power off.

2.Connect the 8-pin connector of the TP tool to the connector CN7 on the HN-260 board.

3.Connect the 5-pin connector of the TP tool to the connector CN3 on the CTL-10 board.

4.Select the switches S1-1 and S1-2 on the HN-260 board to the OFF.

5.Connect an oscilloscope. CH-1 : PB CUE/TP tool

6.Turn the power on.

7.Insert the alignment tape ZR2-1/P.

5-20

DVW-790WS/709WS/707

 

DVW-790WSP/709WSP/707P P2V1

Page 230
Image 230