3-28 DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
Reinstallation
Required tool
.Sealant TSE-392W : 7-432-950-03
1. Remove the remaining old sealant from the
surface of the inside panel ( portion in the
figure) using a flatbrade screwdriver.
2. Apply the sealant to the areas in the
figures “1 Inside panel” and “2 Card door
assembly” as shown, to a width of 1 to 2 mm.
n
As for the areas nearby the hole for the open
switch, be careful not to exceed 1 mm of the
width of applying sealant.
Take care not to ooze the sealant to the
outside surface. If it is out, wipe the sealant
off.
3. Reattach the card door assembly by reversing
the removing steps.
Standard tightening torque :
10 x 10_2 N.m {1.0 kgf.cm}
3-8. Replacing the 40-pin FittingAssembly
Refer to Section “3-1-4. Replacing the CI-20 and
CI-21 Boards”.
VR-248 board
Precision
P 1.4x3.5
Precision
P 1.4x3.5
CN10
Flexible card wire
Card door
assembly
1 mm
Sealant
Sealant
Open switch
hole
1 Inside panel 2 Card door assembly
Removal
1. Open the inside panel.
2. Disconnect the flexible card wire from the
connector (CN10) on the VR-248 board.
3. Remove the five precision screws to remove
the card door assembly.
3-7. Replacing the Card Door Assembly
3-7. Replacing the Card Door Assembly