2-1. Service Mode

No.

Page

Item

Setup

Description

37

OPERATION 2

AWB LEVEL GATE

[ON]/OFF

Selects the desired detection mode for the white balance auto-

 

 

 

 

matic adjustment.

 

 

 

 

ON

:

Detects the white level to adjust the white balance.

 

 

 

 

OFF

:

Detects the signal level around the center of the screen

 

 

 

 

 

to adjust the white balance.

 

 

COLOR VF

[COMP]/VBS

Selects the output signal to VF when a color VF is used (compo

 

 

 

 

nent or VBS signal).

 

 

 

 

If noise when switching the RET video (VBS) is annoying, select

 

 

 

 

the VBS position.

 

 

REVERSE IMAGE

ON/[OFF]

Turns ON/OFF the image inversion function. (This item is displayed

 

 

 

 

only when the image inverter board BKDW-704 is installed.)

 

 

 

 

 

 

 

H DELAY

X ([0])

Adjust the H phase during image inversion mode. (This item is

 

 

 

 

displayed only when the image inverter board BKDW-704 is installed.)

 

 

 

 

 

 

 

REC TALLY

[UPPER]/BOTH

Selection of LEDs inside VF to be turned on during REC.

 

 

 

 

UPPER : Only the LED in the top center of VF

 

 

 

 

BOTH

: Only the LEDs in the top center and bottom center of VF

 

 

 

 

 

 

 

TIME CODE DISP

[OFF]/VF/TEST/

Turns ON/OFF the function of outputting the time code to TEST

 

 

 

BOTH

OUT and on the VF screen.

 

 

 

 

OFF

: Outputs no time code.

 

 

 

 

VF

: Outputs the time code to the viewfinder only.

 

 

 

 

TEST : Outputs the time code to the TEST OUT connector only.

 

 

 

 

BOTH : Outputs the time code to the viewfinder and TEST OUT connector.

 

 

 

 

 

 

 

LOOP RECORDING

[OFF]/1/2/4/8 (sec)

Turns ON/OFF the loop recording function and selects the loop

 

 

 

 

recording time. (This item is displayed only when the picture

 

 

 

 

cache board BKDW-703 is installed.)

 

 

 

 

 

38

FRM SHUTTER

 

 

(This page is displayed only when the frame shutter unit BKDW-

 

 

 

 

705 is installed.)

 

 

 

 

 

 

 

FRM SHUTTER

ON/[OFF]

Turns ON/OFF the frame shutter function.

 

 

UNIT

 

 

 

 

 

 

 

 

 

 

TOTAL OP TIME

 

Indicates the running hours of the frame shutter function.

 

 

 

 

 

39

SG ADJ.

H BLANKING

X ([0])

Sets the H blanking width.

 

 

WIDTH

 

 

 

 

 

 

 

 

 

 

V BLANKING

[20H]/21H

Set the V blanking width (20H/21H). (NTSC only)

 

 

WIDTH

 

 

 

 

 

 

 

 

40

ENC ADJ.

BURST START

X ([0])

Sets the starting position of the burst signal of the encoder output.

 

 

 

 

 

 

 

BURST STOP

X ([0])

Sets the ending position of the burst signal of the encoder output.

 

 

 

 

 

 

 

R-Y CAR. BAL.

X ([0])

Adjusts the R-Y carrier balance of the encoder output.

 

 

 

 

 

 

 

B-Y CAR. BAL.

X ([0])

Adjusts the B-Y carrier balance of the encoder output.

 

 

 

 

 

 

 

SYNC START

X ([0])

Sets the starting position of the sync signal of the encoder output.

 

 

 

 

 

 

 

SYNC STOP

X ([0])

Sets the ending position of the sync signal of the encoder output.

 

 

 

 

 

 

 

INT SC FREQ.

X ([0])

Adjusts the carrier frequency . (NTSC only)

 

 

 

 

 

41

DATA RESET

 

 

Returns the setup values and adjustment values of the respective

 

 

 

 

modes to the default setting when shipped from factory.

 

 

 

 

 

 

 

USER

To be executed by

Resets the data that has been set by the user mode.

 

 

 

pressing the rotary

 

 

 

 

 

encoder.

 

 

 

 

 

 

 

 

 

ENGINEER

To be executed by

Resets the data that has been set by the engineer mode.

 

 

 

pressing the rotary

 

 

 

 

 

encoder.

 

 

 

 

 

 

 

 

 

SERVICE

To be executed by

Resets the data that has been set by the service mode.

 

 

 

pressing the rotary

 

 

 

 

 

encoder.

 

 

2-14

 

 

 

 

DVW-790WS/709WS/707

DVW-790WSP/709WSP/707P P2V1

Page 38
Image 38
Sony DVW-790WS/790WSP Operation AWB Level Gate, Color VF, Reverse Image, Delay, REC Tally, Both, Loop Recording, Car. Bal