2-14 DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
2-1. Service Mode
No. Page Item Setup Description
37 OPERATION 2 AWB LEVEL GATE [ON]/OFF Selects the desired detection mode for the white balance auto-
matic adjustment.
ON : Detects the white level to adjust the white balance.
OFF : Detects the signal level around the center of the screen
to adjust the white balance.
COLOR VF [COMP]/VBS Selects the output signal to VF when a color VF is used (compo
nent or VBS signal).
If noise when switching the RET video (VBS) is annoying, select
the VBS position.
REVERSE IMAGE ON/[OFF]
Turns ON/OFF the image inversion function. (This item is displayed
only when the image inverter board BKDW-704 is installed.)
H DELAY X ([0]) Adjust the H phase during image inversion mode. (This item is
displayed only when the image inverter board BKDW-704 is installed.)
REC TALLY [UPPER]/BOTH Selection of LEDs inside VF to be turned on during REC.
UPPER: Only the LED in the top center of VF
BOTH : Only the LEDs in the top center and bottom center of VF
TIME CODE DISP [OFF]/VF/TEST/ Turns ON/OFF the function of outputting the time code to TEST
BOTH OUT and on the VF screen.
OFF : Outputs no time code.
VF : Outputs the time code to the viewfinder only.
TEST : Outputs the time code to the TEST OUT connector only.
BOTH:
Outputs the time code to the viewfinder and TEST OUT connector.
LOOP RECORDING
[OFF]/1/2/4/8 (sec)
Turns ON/OFF the loop recording function and selects the loop
recording time. (This item is displayed only when the picture
cache board BKDW-703 is installed.)
38 FRM SHUTTER (This page is displayed only when the frame shutter unit BKDW-
705 is installed.)
FRM SHUTTER ON/[OFF] Turns ON/OFF the frame shutter function.
UNIT
TOTAL OP TIME Indicates the running hours of the frame shutter function.
39 SG ADJ. H BLANKING X ([0]) Sets the H blanking width.
WIDTH
V BLANKING [20H]/21H Set the V blanking width (20H/21H). (NTSC only)
WIDTH
40 ENC ADJ. BURST START X ([0]) Sets the starting position of the burst signal of the encoder output.
BURST STOP X ([0]) Sets the ending position of the burst signal of the encoder output.
R-Y CAR. BAL. X ([0]) Adjusts the R-Y carrier balance of the encoder output.
B-Y CAR. BAL. X ([0]) Adjusts the B-Y carrier balance of the encoder output.
SYNC START X ([0]) Sets the starting position of the sync signal of the encoder output.
SYNC STOP X ([0]) Sets the ending position of the sync signal of the encoder output.
INT SC FREQ. X ([0]) Adjusts the carrier frequency . (NTSC only)
41 DATA RESET Returns the setup values and adjustment values of the respective
modes to the default setting when shipped from factory.
USER To be executed by Resets the data that has been set by the user mode.
pressing the rotary
encoder.
ENGINEER To be executed by Resets the data that has been set by the engineer mode.
pressing the rotary
encoder.
SERVICE To be executed by Resets the data that has been set by the service mode.
pressing the rotary
encoder.