5-6. CUE Head Azimuth Check

5-6. CUE Head Azimuth Check

Notes

.The check whether the CUE head azimuth is correctly adjusted or not is extremely difficult from the point of the tape running system.

Do not perform this check, but adjust the CUE head azimuth according to the following procedures.

.The CUE head azimuth check the position and height adjustments of the CUE head.

.After carrying out the CUE head azimuth adjustment, be sure to carry out the adjustments or checks of the CUE head.

Tools

 

. Alignment tape, ZR2-1 (NTSC)

: 8-960-073-11

. Alignment tape, ZR2-1P (PAL)

: 8-960-073-61

. TP tool

: J-6420-910-A

. Oscilloscope

 

Setting

1.Turn the power off.

2.Connect the 8-pin connector of the TP tool to the connector CN7 on the HN-260 board.

3.Connect the 5-pin connector of the TP tool to the connector CN3 on the CTL-10 board.

4.Set the switches S1-1 and S1-2 on the HN-260 board to OFF.

5.Connect an oscilloscope. CH-1: PB CUE/TP tool

6.Turn the power on.

7.Insert the alignment tape ZR2-1/P.

DVW-790WS/709WS/707