8-18. Zebra Adjustment

8-18. Zebra Adjustment

Preparation

.ZEBRA switch (viewfinder) → ON

.On the setup menu, set as follows.

PAGE

: S12*FUNCTION 1/2

ITEM

: TEST OUT

→ R, G or B

PAGE

: S15*VF SETTING

 

ITEM

: ZEBRA SELECT

→ 1

ITEM

: ZEBRA1 APT. LVL → 1 %

.OUTPUT/DCC switch (inside panel) → CAM/ON

.Shoot a grayscale chart in the full underscanned monitor

frame.

 

 

 

 

 

 

 

Equipment

: Waveform monitor

Test point

: TEST OUT connector

Setting point

: 1Lens IRIS

Spec.

: A = 100 ± 2 IRE (NTSC)

 

A = 700 ± 14 mV (PAL)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustment Procedure

Equipment

: Black and white monitor

Test point

: TEST OUT connector

1. On the setup menu, adjust as follows.

PAGE

: S15*VF SETTING

ITEM

: ZEBRA1 DET. LVL

Spec.

: Set the condition that zebra pattern appears

 

at the portions A.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. On the setup menu, set as follows.

PAGE

: S12*FUNCTION 1/2

ITEM

: TEST SAW → ON

3. On the setup menu, adjust as follows.

PAGE

: S15*VF SETTING

ITEM

: ZEBRA1 APT. LVL (Factory setting : 10 %)

Spec.

: Adjust for the desired width of detection.

4.

On the setup menu, set as follows.

 

PAGE

: S12*FUNCTION 1/2

 

ITEM

: TEST SAW → OFF

5.

On the setup menu, set as follows.

 

PAGE

: S15*VF SETTING

 

ITEM

: ZEBRA SELECT → 2

6.

On the setup menu, adjust as follows.

 

PAGE

: S15*VF SETTING

 

ITEM

: ZEBRA2 DET. LVL

 

Spec.

: Set the condition that zebra pattern appears

 

 

at the portion B.

B

Setting After Adjustment

.On the setup menu, set as follows.

PAGE

: S15*VF SETTING

ITEM

: ZEBRA SELECT → 1

PAGE

: S12*FUNCTION 1/2

ITEM

: TEST OUT → ENC

8-24

DVW-790WS/709WS/707

DVW-790WSP/709WSP/707P P2V1

Page 310
Image 310
Sony DVW-790WS/790WSP, DVW-709WS/709WSP manual ZEBRA1 APT. LVL → 1 %