3-2. Replacing the CCD Unit and Its Components

n

The removal and reinstallation procedures of the filter knob differ depending on the model.

2.Removing the ND Filter Knob

DVW-790WS/790WSP/709WS/709WSP : Loosen the two setscrews to remove the ND filter knob.

Tool : L-shaped hex. wrench (s=0.89 mm) DVW-707/707P :

Loosen the setscrew to remove the filter knob. Tool : L-shaped hex. wrench (s=1.5 mm)

3.Removing the CC Filter Knob

(DVW-790WS/790WSP/709WS/709WSP)

Loosen the two setscrews to remove the CC filter knob.

Tool : L-shaped hex. wrench (s=0.89 mm)

4. Removing the CCD Unit

Remove the four hexagon socket bolts (M 3x8) and the four washers (SW3) to remove the CCD unit from the front frame assembly.

Tool : L-shaped hex. wrench (s=2.5 mm)

DVW-790WS/790WSP/709WS/709WSP

Front frame assembly

SW

 

 

 

 

CCD unit

Hexagon

 

 

socket

 

 

bolts

 

CC

(M 3x8)

SW

 

 

filter knob

DVW-707/707P

 

ND filter knob

Filter knob

 

 

 

 

Setscrews (WP 2x3)

Setscrew (WP 3x3)

 

3-10

DVW-790WS/709WS/707

DVW-790WSP/709WSP/707P P2V1

Page 66
Image 66
Sony Removing the ND Filter Knob, Removing the CC Filter Knob DVW-790WS/790WSP/709WS/709WSP, Removing the CCD Unit