8-5. TEST OUT Level Adjustment

8-6. Modulator Balance Adjustment

8-5. TEST OUT Level Adjustment

Preparation

.OUTPUT/DCC switch (inside panel) → BARS

.On the setup menu, set as follows.

PAGE

: S23*LEVEL 6

ITEM

: TEST OUT → R, G or B

 

Adjustment Procedure

Equipment

: Waveform monitor

Test point

: TEST OUT connector

1. On the setup menu, adjust as follows.

PAGE

: S23*LEVEL 6

ITEM

: RGB SYNC

Spec.

: A = 40 ± 2 IRE (NTSC)

 

A = 300 ± 14 mV (PAL)

2. On the setup menu, adjust as follows.

PAGE

: S23*LEVEL 6

ITEM

: RGB SETUP

Spec.

: B = 7.5 ± 0.5 IRE (NTSC)

 

B = 0 ± 3 mV (PAL)

3. On the setup menu, adjust as follows.

PAGE

: S23*LEVEL 6

ITEM

: RGB LEVEL

Spec.

: C = 100 ± 2 IRE (NTSC)

 

C = 700 ± 14 mV (PAL)

NTSC

PAL

R

R

C

C

B

B

A

A

 

Setting After Adjustment

.On the setup menu, set as follows.

PAGE

: S23*LEVEL 6

ITEM

: TEST OUT → ENC

8-6. Modulator Balance Adjustment

Preparation

.WHITE BAL switch (inside panel) → PRST

.OUTPUT/DCC switch (inside panel) → CAM/ON

.MENU ON/OFF/PAGE switch (inside panel) → OFF

Adjustment Procedure

1.AUTO W/B BAL switch (front panel) → BLK Hold this switch in BLK state untilthe message “ _MOD BAL_” on the viewfinder is displayed .

2.A few seconds later after releasing the switch, check that the message “BLACK OK” is displayed on the viewfinder.

8-8

DVW-790WS/709WS/707

DVW-790WSP/709WSP/707P P2V1

Page 294
Image 294
Sony DVW-790WS/790WSP, DVW-709WS/709WSP manual Spec = 100 ± 2 IRE Ntsc = 700 ± 14 mV PAL