7-25
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
7-16-5. Detail Level Adjustment (16:9)
16:9 mode
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : DETAIL ON
ITEM : TEST OUT ENC
.Shoot a grayscale chart (16:9) in the full underscanned
monitor frame.
Equipment :Waveform monitor
Test point : TEST OUT connector
Setting point : 1 Lens IRIS
Spec. : A = 80 ±2 IRE (NTSC)
A = 560 ±14 mV (PAL)
Adjustment Procedure
Equipment : Waveform monitor
Test point : TEST OUT connector
1. Select the 16:9 mode.
PAGE :S14*WIDE SCREEN
ITEM :16:9/4:3 MODE 16:9
2. On the setup menu, adjust as follows.
PAGE :S16*LEVEL 1
ITEM : DETAIL LVL (Factory setting: 0)
Spec. : Adjust to the detail amount which is
added to each step in the grayscale
chart for the customer’s preferences.
7-16-6. Knee Aperture Adjustment (16:9)
16:9 mode
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : DETAIL ON
ITEM : TEST OUT ENC
PAGE : S17*LEVEL 2
ITEM : KNEE APT. ON
.OUTPUT/DCC switch (inside panel) CAM/ON
.Shoot a grayscale chart (16:9) in the full underscanned
monitor frame.
Equipment : Waveform monitor
Test point : TEST OUT connector
Setting point : 1 Lens IRIS
Spec. : A = 100 ±2 IRE (NTSC)
A = 700 ±14 mV (PAL)
.GAIN switch (inside panel) M (9 dB)
Adjustment Procedure
Equipment : Waveform monitor
Test point : TEST OUT connector
1. Select the 16:9 mode.
PAGE :S14*WIDE SCREEN
ITEM :16:9/4:3 MODE 16:9
2. On the setup menu, adjust as follows.
PAGE :S17*LEVEL 2
ITEM : K.APT.LVL
Spec. : Adjust the peak-to-peak level of the
noise at the third steps from the top
(portion B) in the grayscale chart, as
desired. (Reference level is 40 mV)
A
A
7-16. Detail Signal Adjustment (16:9)
B