7-26 DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
7-16-7. H Detail Black Clip Adjustment (16:9)
16:9 mode
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : DETAIL ON
ITEM : TEST OUT ENC
.OUTPUT/DCC switch (inside panel) CAM/ON
.Shoot a grayscale chart (16:9) in the full underscanned
monitor frame.
Equipment : Waveform monitor
Test point : TEST OUT connector
Setting point : 1 Lens IRIS
Spec. : Open the lens iris by one step from the
reference setting
A = 100 ±2 IRE (NTSC)
A = 700 ±14 mV (PAL)
.Select the line at the center white portion of the gray-
scale chart.
Adjustment Procedure
Equipment :Waveform monitor
Test point : TEST OUT connector
1. Select the 16:9 mode.
PAGE :S14*WIDE SCREEN
ITEM : 16:9/4:3 MODE 16:9
2. On the setup menu, adjust as follows.
PAGE : S16*LEVEL 1
ITEM : DTL H B. CLIP (Factory setting : 0)
Spec. : Set the edges of portion B to the
desired clip level.
7-16-8. V Detail Black Clip Adjustment (16:9)
16:9 mode
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : DETAIL ON
ITEM : TEST OUT ENC
.OUTPUT/DCC switch (inside panel) CAM/ON
.Shoot a white window chart (16:9) in the full under-
scanned monitor frame.
Equipment : Waveform monitor
Test point : TEST OUT connector
Setting point : 1 Lens IRIS
Spec. :Open the lens iris by one step from the
reference setting
A = 100 ±2 IRE (NTSC)
A = 700 ±14 mV (PAL)
.Select the line at the bottom of the center white portion
in the white window chart.
Adjustment Procedure
Equipment : Waveform monitor
Test point : TEST OUT connector
1. Select the 16:9 mode.
PAGE : S14*WIDE SCREEN
ITEM : 16:9/4:3 MODE 16:9
2. On the setup menu, adjust as follows.
PAGE : S16*LEVEL 1
ITEM : V DTL B. CLIP (Factory setting : 0)
Spec. : Set the level of portion B to the desired
level.
7-16. Detail Signal Adjustment (16:9)
A
B
A
B