7-14. Flare Adjustment

16:9 mode

Preparation

.On the setup menu, set as follows.

PAGE

: S24*LEVEL 7

ITEM

: TEST OUT → ENC

.OUTPUT/DCC switch (inside panel) → CAM/ON

.Shoot a grayscale chart (16:9) in the full underscanned monitor frame.

Equipment

: Waveform monitor

Test point

: TEST OUT connector

Setting point

: 1Lens IRIS

Spec.

: Open the lens iris by one step from the

reference setting

A = 100 ±2 IRE (NTSC) A = 700 ±14 mV (PAL)

A

Adjustment Procedure

Equipment

: Waveform monitor

Test point

: TEST OUT connector

 

7-14. Flare Adjustment

4. On the setup menu, adjust as follows.

PAGE

: S24*LEVEL 7

ITEM

: R FLARE

Spec.

: Minimize the carrier leakage at portion C

C

5. On the setup menu, adjust as follows.

PAGE

: S24*LEVEL 7

ITEM

: B FLARE

Spec.

: Minimize the carrier leakage at portion C.

6. Repeat steps 4 and 5 several times.

1.

Select the 16:9 mode.

 

PAGE

: S14*WIDE SCREEN

 

ITEM

: 16:9/4:3 MODE → 16:9

2.

On the setup menu, set as follows.

 

PAGE

: S24*LEVEL 7

 

ITEM

: G FLARE → 0

3.Select portion B by using the waveform monitor.

B

DVW-790WS/709WS/707

7-19

DVW-790WSP/709WSP/707P P2V1

Page 271
Image 271
Sony DVW-709WS/709WSP, DVW-790WS/790WSP manual Flare Adjustment