7-2. VCO CONT Frequency Check

Note

.Conduct this check when the TG-207/207P, ES-23/23P

boards or CCD block is only replaced.

.Before measurement, turn the power ON and warm up the camcorder for about 10 munites.

Preparation

.Connect as follows.

VIDEO

 

 

GEN

SC

 

 

IN

OUT

LOCK

OUT

 

 

 

 

 

DVW-790WS/709WS

SG

 

 

 

Frequency

DVW-790WSP/709WSP

 

 

 

 

counter

.On the setup menu, set as follows.

PAGE

: S12*FUNCTON 1/2

ITEM

: TEST OUT → ENC

 

 

Adjustment Procedure

 

1. Equipment

: Frequency counter, Oscilloscope

Test point

: VIDEO OUT connector

GND

: E1 (DCP-17 board)

Spec.

: 3,579,545

±10 Hz (NTSC)

 

4,433,618

±5 Hz (PAL)

If the measured value is out of the specification, adjust it as follows.

2. On the setup menu, adjust as follows.

PAGE

: S40*ENC ADJ.

ITEM

: INT SC FREQUENCY

Spec.

: 3,579,545 ±10 Hz (NTSC)

4,433,618 ±5 Hz (PAL)

C D E F