Installation

5. FE Head Installation

Insert two bosses of the FE head into the longitudi- nal hole of the entrance head assembly, and tighten the one screw.

The standard tightening torque value :

9x10_2 N.m {0.9 kgf.cm}

6.Entrance Head Assembly Installation

(1) Attach the entrance head assembly with the mechanism deck using the two screws.

The standard tightening torque value :

9x10_2 N.m {0.9 kgf.cm}

(2) Attach the connector.

 

 

4-2. Parts Replacement

 

 

 

DVW-707: 10001 through 10055

DVW-707P:

40001 through 40190

DVW-709WS: 10001 through 10125

DVW-709WSP: 40001 through 40255

DVW-790WS: 10001 through 10160

DVW-790WSP: 40001 through 40510

Boss

Boss

Longitudinal hole

M 2x5

Adjustment After Replacement

7.Tape Running Adjustment

(Refer to section 5-1.)

DVW-790WS/709WS/707 P2V1

DVW-707: 10056 and higher

DVW-707P: 40191 and higher

DVW-709WS: 10126 and higher

DVW-709WSP: 40256 and higher

DVW-790WS: 10161 and higher

DVW-790WSP: 40511 and higher

Boss

Boss

Longitudinal hole

M 2x5

4-111

DVW-790WSP/709WSP/707P P2V1

Page 195
Image 195
Sony DVW-709WS/709WSP, DVW-790WS/790WSP manual Installation FE Head Installation, Entrance Head Assembly Installation