7-1. General Information for Electrical Adjustment

Initial Setting

Before performing adjustment, set switches as follows, If the setting of the GAIN switch is changed from the factory set value, reset it to its original value by referring to the operation manual.

Inside panel :

 

VTR SAVE/STBY switch

→ STBY

GAIN switch

→ L (0 dB)

OUTPUT/DCC switch

→ CAM/OFF

MENU ON/OFF/PAGE switch

→ OFF

WHITE BAL switch

→ PRST

Front panel :

 

SHUTTER switch

→ OFF

Filter selector

→ 1B

Lens :

 

LENS

→ MANU

IRIS

→ C (CLOSE)

Setup menu :

 

. S06*MASTER GAIN

 

LOW

→ 0 dB

MID

→ 9 dB

HIGH

→ 18 dB

. S12*FUNCTION 1/2

 

TEST OUT

→ ENC

DETAIL

→ ON

APERTURE

→ ON

SKIN TONE DETAIL

→ OFF

MATRIX

→ ON

GAMMA

→ ON

BLACK GAMMA

→ OFF

TEST SAW

→ OFF

CHROMA

→ ON

CROSS COLOR FLT.

→ OFF (NTSC only)

. S13*FUNCTION 2/2

 

GENLOCK

→ ON

CAM RET

→ OFF

FILTER INHBIT

→ OFF

. S21*LEVEL 4

 

KNEE SATURATION

→ 0

KNEE

→ ON

WHITE CLIP

→ ON

.S22*LEVEL 5

R-Y

→ ON

B-Y

→ ON

7-2