8-22 DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
8-16-7. H Detail Black Clip Adjustment
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : DETAIL ON
ITEM : TEST OUT ENC
.OUTPUT/DCC switch (inside panel) CAM/ON
.Shoot a grayscale chart in the full underscanned monitor
frame.
Equipment : Waveform monitor
Test point : TEST OUT connector
Setting point : 1 Lens IRIS
Spec. : Open the lens iris by one step from the
reference setting
A = 100 ±2 IRE (NTSC)
A = 700 ±14 mV (PAL)
.Select the line at the center white portion of the gray-
scale chart.
Adjustment Procedure
Equipment : Waveform monitor
Test point : TEST OUT connector
1. On the setup menu, adjust as follows.
PAGE : S16*LEVEL 1
ITEM : DTL H B. CLIP (Factory setting : 0)
Spec. : Set the edges of portion B to the
desired clip level.
8-16-8. V Detail Black Clip Adjustment
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.On the set menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : DETAIL ON
ITEM : TEST OUT ENC
.OUTPUT/DCC switch (inside panel) CAM/ON
.Shoot a white window chart in the full underscanned
monitor frame.
Equipment : Waveform monitor
Test point : TEST OUT connector
Setting point : 1 Lens IRIS
Spec. : Open the lens iris by one step from the
reference setting
A = 100 ±2 IRE (NTSC)
A = 700 ±14 mV (PAL)
.Select the line at the bottom of the center white portion
in the white window chart.
Adjustment Procedure
Equipment : Waveform monitor
Test point : TEST OUT connector
1. On the setup menu, adjust as follows.
PAGE : S16*LEVEL 1
ITEM : DTL V B. CLIP (Factory setting : 0)
Spec. : Set the level of portion B to the desired
level.
8-16. Detail Signal Adjustment
A
BB
A