7-19. Zebra Adjustment

7-19. Zebra Adjustment

Preparation

.ZEBRA switch (viewfinder) → ON

.On the setup menu, set as follows.

PAGE

: S12*FUNCTION 1/2

ITEM

: TEST OUT

→ R, G or B

PAGE

: S15*VF SETTING

 

ITEM

: ZEBRA SELECT

→ 1

ITEM

: ZEBRA1 APT. LVL → l%

.OUTPUT/DCC switch (inside panel) → CAM/ON

.Shoot a grayscale chart in the full underscanned monitor

frame.

 

 

 

Equipment

: Waveform monitor

Test point

: TEST OUT connector

Setting point

: 1Lens IRIS

Spec.

: A = 100

±2 IRE (NTSC)

 

A = 700

±14 mV (PAL)

 

 

 

 

A

Adjustment Procedure

Equipment : Black and white monitor

Test point : TEST OUT connector

1. On the setup menu, adjust as follows.

PAGE

: S15*VF SETTING

ITEM

: ZEBRA1 DET. LVL

Spec.

: Set the condition that zebra pattern

appears at the portions A.

A

A

3.

On the setup menu, adjust as follows.

 

PAGE

: S15*VF SETTING

 

ITEM

: ZEBRA1 APT.LVL

 

 

(Factory setting: 10%)

 

Spec.

: Adjust for the desired width of detection.

4.

On the setup menu, set as follows.

 

PAGE

: S12*FUNCTION 1/2

 

ITEM

: TEST SAW → OFF

5.

On the setup menu, set as follows.

 

PAGE

: S15*VF SETTING

 

ITEM

: ZEBRA SELECT → 2

6.

On the setup menu, adjust as follows.

 

PAGE

: S15*VF SETTING

 

ITEM

: ZEBRA2 DET. LVL

 

Spec.

: Set the condition that zebra pattern

 

 

appears at the portion B.

B

Setting After Adjustment

.On the setup menu, set as follows.

PAGE

: S15*VF SETTING

ITEM

: ZEBRA SELECT → 1

PAGE

: S12*FUNCTION 1/2

ITEM

: TEST OUT → ENC

2. On the setup menu, set as follows.

PAGE

: S12*FUNCTION 1/2

ITEM

: TEST SAW → ON

7-32

DVW-790WS/709WS/707

DVW-790WSP/709WSP/707P P2V1

Page 284
Image 284
Sony DVW-790WS/790WSP, DVW-709WS/709WSP manual Zebra Adjustment