1-3. Disconnecting/Reconnecting Flexible Card Wires

1-4. IC Link

1-3. Disconnecting/Reconnecting Flexible Card Wires

The three flexible card wires are used in the connection of the MB-810 board and the TC-101 board.

Be careful not to bend forcedly these flexible card wires. Crease of wire can seriously shorten its life.

n

Turn off the power, and then unplug the power cord or remove the battery before disconnecting/reconnecting the wires.

Disconnecting

1.Slide portions A in the direction of the arrow to unlock the connector, and then pull the flexible card wire out.

Flexible card wire

Slide portions A

flexible card wire

Reconnecting

1.Check to see that the conductive surface (silver side) of the flexible card wire is not soiled with dust.

2.Slide portions A in the direction of the arrow, and then insert the flexible card wire into the connector with the

conductive surface (silver side) down. n

Be sure to insert the wire straightforward.

3.Slide portions A in the reverse direction to lock the connector.

1-4. IC Link

w

The IC link is critical for safe operation.

To avoid danger of a fire or electric shock, be sure use the specified component as a spare part when replacing it.

c

Replacement of the IC link of the plugged-in unit may be hazardous.

Be sure to turn off the power, and then unplug the cord from the DC IN connector before replacing the IC link.

An IC link is mounted on the B side of the HP-93 board. This will blow when the overcurrent flows because of internal circuit failure. If it blows, check the circuit for overcurrent after turning off the power.

And then, replace the IC link with specified part.

Board

Ref. No.

Description

Part No.

HP-93

F1

IC Link 2A

1-533-282-21

 

 

 

 

1-8

DVW-790WS/709WS/707

DVW-790WSP/709WSP/707P P2V1

Page 20
Image 20
Sony DVW-790WS/790WSP, DVW-709WS/709WSP manual Disconnecting/Reconnecting Flexible Card Wires, IC Link