8-9. VA Gain Adjustment

Note

Use an 89.9%-reflective chart in this adjustment as possi- ble. (Refer to Section 8-1-4.)

Preparation

.OUTPUT/DCC switch (inside panel) → CAM/ON

.Shoot a grayscale chart in the full underscanned monitor frame.

.WHITE BAL switch (inside panel) → PRST

.AUTO W/B BAL switch (front panel) → BLK (Perform the automatic black balance adjustment.)

.On the setup menu, set as follows.

PAGE

: S35*PRESET WHT

 

ITEM

: COLOR TEMP <P> : 3200

ITEM

: R GAIN <P>

: 0

ITEM

: B GAIN <P>

: 0

 

 

Adjustment Procedure

 

1. Equipment

: Oscilloscope

 

Test point

: TP1 (VA-191 board)

 

Setting point : 1Lens IRIS

 

Spec.

: A = 320 ± 8 mV

 

A

8-9. VA Gain Adjustment

4. On the setup menu, set as follows.

PAGE

: S12*FUNCTION 1/2

ITEM

: TEST OUT → ENC

ITEM

: GAMMA → OFF

5.Select portion C by using the waveform monitor.

C

6.Set the waveform monitor to the CHROMA mode.

7.Equipment : Waveform monitor

Test point

: TEST OUT connector

Adj. point

: 1RV101 (VA-191 board (R GIAN))

 

1RV301 (VA-191 board (B GAIN))

Spec.

: Minimize carrier leakage D by using

 

the variable resistors alternately.

D

Setting After Adjustment

.On the setup menu, set as follows.

PAGE

: S12*FUNCTION 1/2

ITEM

: GAMMA → ON

2.

On the setup menu, set as follows.

 

PAGE

: S12*FUNCTION 1/2

 

ITEM

: TEST OUT → G

3.

Equipment

: Waveform monitor

 

Test point

: TEST OUT connector

 

Adj. point

: 1RV201 (VA-191 board (G GAIN))

 

Spec.

: B =

100

± 2 IRE (NTSC)

 

 

B =

700

± 10 mV (PAL)

B

A

1

2

3

B

1

RV301

D

C

RV201

1

1

TP1RV101

E

DVW-790WS/709WS/707

VA-191 board (A side)

8-11