13. On the setup menu, adjust as follows.

PAGE

: S39*SG ADJ.

ITEM

: H BLANKING WIDTH

Spec.

: D =

10.9

±0.2 us (NTSC)

 

D =

12.0

±0.3 us (PAL)

20 IRE (NTSC)

 

 

D

 

 

 

140 mV (PAL)

 

14. On the setup menu, set as follows. (For only NTSC)

PAGE

: S39*SG ADJ.

ITEM

: V BLANKING WIDTH

Spec.

: 20H or 21H

7-4. ENC OUT Adjustment

7-4-3. INT SC Phase Adjustment

Note

The following adjustment procedures are described under the condition by using the Tektronix 1750/1751. If any other measuring instrument is used, perform the adjust- ment according to the operation manual attached to it.

Preparation

.On the setup menu, set as follows.

PAGE

: S24*LEVEL 7

 

 

 

ITEM

: TEST OUT → ENC

 

 

Adjustment Procedure

 

 

 

Equipment

: Waveform/Vector monitor

 

 

(SC-H Phase measuring mode)

Test point

: TEST OUT connector

 

 

1. On the setup menu, adjust as follows.

 

 

PAGE

: S28*LEVEL 11

 

 

 

ITEM

: SC PHASE

 

 

 

Spec.

: Coincide the beam spot of the burst

 

(SC) with the direction of the beam

 

spot of H.

 

 

 

 

MG

 

 

 

 

R

R

 

MG

 

 

 

 

 

 

 

YL

 

YL

 

 

 

 

 

 

 

B

 

 

B

 

 

 

 

G

CY

G

CY

 

 

 

 

 

 

 

(For NTSC)

(For PAL)

 

Setting After Adjustment

A B

1

2

3

FL12

1

4

5

DVW-790WS/709WS/707

C

Connect the waveform monitor to the TEST OUT connec- tor.

D E F G

ES-23/23P board (A side)

7-9

DVW-790WSP/709WSP/707P P2V1

Page 261
Image 261
Sony DVW-709WS/709WSP, DVW-790WS/790WSP manual INT SC Phase Adjustment, Blanking Width, Setting After Adjustment, IRE Ntsc