1. On the setup menu, adjust as follows.
PAGE : S16*LEVEL 1
ITEM : DTL FREQ. (Factory setting: 0)
Spec. : Set the desired width at the edge of portion B.
B
Note
After this adjustment, be sure to perform Section 8-16-4 “H/V Ratio Adjustment”, and Section 8-16-5 “Detail Level Adjustment”, in that order.
8-20
Equipment Test point
: Waveform monitor
: TEST OUT connector
A
. Select the line at the center white portion of the gray- scale chart.
Adjustment Procedure
: Waveform monitor
: TEST OUT connector
: 1Lens IRIS
: A = 100 ± 2 IRE (NTSC) A = 700 ± 14 mV (PAL)
.
.
On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM: DETAIL → ON
ITEM: TEST OUT → ENC OUTPUT/DCC switch (inside panel) → CAM/ON Shoot a grayscale chart in the full underscanned monitor frame.
Equipment Test point Setting point Spec.
.
8-16. Detail Signal Adjustment
8-16-3. Detail Frequency Adjustment
Note
Perform this adjustment, if necessary, to suit the custom- er’s preferences.
Preparation

8-16-4. H/V Ratio Adjustment

Preparation

.On the setup menu, set as follows.

PAGE

: S12*FUNCTION 1/2

ITEM

: DETAIL → ON

ITEM

: TEST OUT → ENC

.OUTPUT/DCC switch (inside panel) → CAM/ON

.Shoot a grayscale chart in the full underscanned monitor frame.

Equipment

: Waveform montior

Test point

: TEST OUT connector

Setting point

: 1Lens IRIS

Spec.

: A = 100

± 2 IRE (NTSC)

 

A = 700

± 14 mV (PAL)

 

 

 

 

 

A

Adjustment Procedure

Equipment

: Black and white monitor

Test point

: TEST OUT connector

1. On the setup menu, adjust as follows.

PAGE

: S16*LEVEL 1

ITEM

: H/V RATIO

Spec.

: Adjust so that the H and V detail amounts

 

which are added are equivalent.

H

V

DVW-790WS/709WS/707

DVW-790WSP/709WSP/707P P2V1

Page 306
Image 306
Sony DVW-790WS/790WSP, DVW-709WS/709WSP manual 16-4. H/V Ratio Adjustment