8-7. TEST SAW Adjustment

Preparation

.OUTPUT/DCC switch (inside panel) → CAM/ON

.WHITE BAL switch (inside panel) → PRST

Adjustment Procedure

Equipment

: Waveform monitor

Test point

: TEST OUT connector

1. On the setup menu, set as follows.

PAGE

: S12*FUNCTION 1/2

ITEM

: GAMMA → OFF

2.AUTO W/B BAL switch (front panel) → BLK (Perform the automatic black balance adjustment.)

3.On the setup menu, adjust as follows.

PAGE

: S21*LEVEL 4

ITEM

: MASTER BLACK

Spec.

: A = 8.0 ± 0.2 IRE (NTSC)

 

A = 2.0 ± 1.0 mV (PAL)

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. On the setup menu, set as follows.

PAGE

: S53*VA ADJ. 2/2

ITEM

: TEST SAW → ON

5. On the setup menu, set as follows.

PAGE

: S53*VA ADJ. 2/2

ITEM

: TEST OUT → G

6. On the setup menu, adjust as follows.

PAGE

: S52*VA ADJ. 1/2

ITEM

: TEST LEVEL

Spec.

: B = 100 ± 2 IRE (NTSC)

 

B = 700 ± 10 mV (PAL)

 

 

 

 

 

 

 

B

DVW-790WS/709WS/707

8-7. TEST SAW Adjustment

Setting After Adjustment

.On the setup menu, set as follows.

PAGE

: S12*FUNCTION 1/2

ITEM

: GAMMA → ON

ITEM

: TEST SAW → OFF

ITEM

: TEST OUT → ENC

8-9

DVW-790WSP/709WSP/707P P2V1