3-2. Replacing the CCD Unit and Its Components
Reinstallation
5. Reinstalling the CCD Unit
(1) Clean the area ( portion in the figure) of
the CCD unit, that contacts the front frame.
(2) Reinstall the CCD unit on the front frame
assembly using the four screws.
Standard tightening torque :
80 x 10_2 N.m {8 kgf.cm}
6. Reinstalling the CC Filter Knob
(DVW-790WS/790WSP/709WS/709WSP)
(1) Turn the lever in the direction of the “Re-
moval” arrow to remove the mount cap.
n
Exercise care to avoid contacting with the
filter surface after removing the mount cap.
(2) Rotate the thick knob axis until the cross
filter (grid patterned filter) can be seen when
viewed from the outside front.
(3) Align the CC filter knob number “A” with
the marking on the front panel as shown, and
then tighten the two setscrews.
Standard tightening torque:
20 x 10_2 N.m {2.0 kgf.cm}
(4) Rotate the CC filter knob and check that the
knob rotates smoothly.
7. Reinstalling the ND Filter Knob
(1) Rotate the thin knob axis until the most light-
colored filter can be seen when viewed from
the outside front.
(2) Align the number “1” of the ND filter knob
or the filter knob with the marking on the
front panel, and then tighten the two set-
screws.
Standard tightening torque
(DVW-790WS/790WSP/709WS/709WSP)
Two screws : 20 x 10_2 N.m {2.0 kgf.cm}
(DVW-707/707P)
Single screw : 53 x 10_2 N.m {5.4 kgf.cm}
(3) Rotate the ND filter knob or the filter knob to
check that the knob rotates smoothly.
(4) Turn the lever in the direction of the “Instal-
lation” arrow, and then reinstall the mount
cap.
1A
Thin knob axis
Thick knob axis
ND filter knob
Front panel
CC filter knob
Mark
Setscrews (A)
(WP 2x3)
Setscrews (B)
(WP 2x3)
1
Mark
Setscrew (WP 3x3)
Number 1
Filter knob
DVW-790WS/709WS
DVW-707
Cleaning
CCD unit
Mount cap
Removal
Installation
Lever