7-29
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
7-17-5. Detail Level Adjustment (4:3) 4:3 mode
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : DETAIL ON
ITEM : TEST OUT ENC
.Shoot a grayscale chart (4:3) in the full underscanned
monitor frame.
Equipment : Waveform monitor
Test point : TEST OUT connector
Setting point : 1 Lens IRIS
Spec. : A = 80 ±2 IRE (NTSC)
A = 560 ±14 mV (PAL)
Adjustment Procedure
Equipment :Waveform monitor
Test point : TEST OUT connector
1.
Select the 4:3 mode.
PAGE : S14*WIDE SCREEN
ITEM : 16:9/4:3 MODE 4:3
2. On the setup menu, adjust as follows.
PAGE : S18*LEVEL 1#4:3
ITEM : DETAIL LVL <4:3>
(Factory setting: 0)
Spec. : Adjust the detail amount which is
added to each step in the grayscale
chart for the customer’s preferences.
7-17-6. Knee Aperture Adjustment (4:3)
4:3 mode
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : DETAIL ON
ITEM : TEST OUT ENC
PAGE : S19*LEVEL 2#4:3
ITEM : KNEE APT. <4:3> ON
.OUTPUT/DCC switch (inside panel) CAM/ON
.Shoot a grayscale chart (4:3) in the full underscanned
monitor frame.
Equipment : Waveform monitor
Test point :TEST OUT connector
Setting point :1 Lens IRIS
Spec. :A = 100 ±2 IRE (NTSC)
A = 700 ±14 mV (PAL)
.GAIN switch (inside panel) M (9 dB)
Adjustment Procedure
Equipment :Waveform monitor
Test point : TEST OUT connector
1.
Select the 4:3 mode.
PAGE : S14*WIDE SCREEN
ITEM : 16:9/4:3 MODE 4:3
2. On the setup menu, adjust as follows.
PAGE : S19*LEVEL 2#4:3
ITEM : K.APT. LVL <4:3>
Spec. : Adjust the peak-to-peak level of the
noise at the third steps from the top
(portion B) in the gray-scale chart, as
desired. (Reference level is 40 mV)5
A
A
7-17. Detail Signal Adjustment (4:3)
B