8-5
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
8-4. ENC OUT Adjustment

8-4-1. ENC Level Adjustment

Preparation
OUTPUT/DCC switch (inside panel) BARS
Adjustment Procedure
Equipment : Waveform monitor
Test point : TEST OUT connector
1. On the setup menu, adjust as follows.
PAGE : S23*LEVEL 6
ITEM : ENC Y SYNC
Spec. : A = 40 ±1 IRE (NTSC)
A = 300 ±7 mV (PAL)
2. On the setup menu, adjust as follows.
PAGE : S40*ENC ADJ.
ITEM : SYNC START
Spec. : B = 1.5 ±0.1 us (NTSC)
B = 1.65 ±0.1 us (PAL)
3. On the setup menu, adjust as follows.
PAGE : S40*ENC ADJ.
ITEM : SYNC STOP
Spec. : C = 4.7 ±0.1 us
4. Check as follows.
Spec. : D = 2.3 ±0.1 us
5. On the setup menu, adjust as follows.
PAGE : S23*LEVEL 6
ITEM : ENC Y SETUP
Spec. : E = 7.5 ±0.5 IRE (NTSC)
E = 0 ±3 mV (PAL)
6. On the setup menu, adjust as follows.
PAGE : S23*LEVEL 6
ITEM : ENC Y LEVEL
Spec. : F = 100 ±2 IRE (NTSC)
F = 700 ±14 mV (PAL)
8-4. ENC OUT Adjustment
V BLANKING
D
50 %
F
E
PAL
F
E
NTSC
B
50%
20 IRE
C
A