8.10Transfer HVPS PCB Unit
(1)Disconnect the four Connectors from the Electrode head.
Transfer HVPS PCB unit
Electrode head
Connector
<Back side>
Fig.
(2)Disconnect the flat cable (CN1) and two connectors (CN5, CN8) from the Registration relay PCB unit.
Note:
-After disconnecting the flat cable(s), check that each cable is not damaged at its end or
-When connecting the flat cable(s), do not insert it at an angle. After insertion, check that the cable is not at an angle.
CN8
CN5
CN1
Registration relay PCB ASSY
Transfer HVPS PCB unit
<Back side>
Fig.
Confidential |