8.10Transfer HVPS PCB Unit

(1)Disconnect the four Connectors from the Electrode head.

Transfer HVPS PCB unit

Electrode head

Connector

<Back side>

Fig. 3-29

(2)Disconnect the flat cable (CN1) and two connectors (CN5, CN8) from the Registration relay PCB unit.

Note:

-After disconnecting the flat cable(s), check that each cable is not damaged at its end or short-circuited.

-When connecting the flat cable(s), do not insert it at an angle. After insertion, check that the cable is not at an angle.

CN8

CN5

CN1

Registration relay PCB ASSY

Transfer HVPS PCB unit

<Back side>

Fig. 3-30

3-47