| Selector No. | Function |
| Setting and Specifications | ||
|
|
|
|
|
|
|
|
|
|
| No. 1 | 2 |
|
1 |
|
| 0 | 0: 15 sec. |
| |
| Maximum OGM recording time | 0 | 1: 20 sec. |
| ||
2 |
|
| ||||
|
| 1 | 0: 30 sec. |
| ||
|
|
|
|
| ||
|
|
|
| 1 | 1: 50 sec. |
|
|
|
|
|
|
|
|
|
|
|
| No. 3 | 4 |
|
| 3 |
| Time length from CML ON to | 0 | 0: 4 sec. |
|
|
| start of pseudo ring backtone | 0 | 1: 3 sec. |
| |
| 4 |
|
| |||
|
| transmission | 1 | 0: 2 sec. |
| |
|
|
|
| |||
|
|
|
| 1 | 1: 1 sec. |
|
5 |
|
| 0: 0 dB | 1: 8 dB | ||
| Attenuator for playback of | 0: 0 dB | 1: 4 dB | |||
| ||||||
| ICM/OGM to the line | 0: 0 dB | 1: 2 dB | |||
8 |
| |||||
|
| 0: 0 dB | 1: 1 dB | |||
|
|
|
| |||
|
|
|
|
|
|
|
- Selectors 1 and 2: Maximum OGM recording time
These selectors set the allowable maximum recording time for an OGM.
- Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission
These selectors set the length of time from
In models with OGM facilities, the settings made by these selectors also apply to the length of time from
- Selectors 5 through 8: Attenuator for playback of ICM/OGM to the line
Setting two or more selectors to “1” produces addition of attenuation assigned to each selector.
This setting is not limited by selector 8 on WSW23.