< WSW24 >

 

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

 

 

 

 

No. 1

2

 

1

 

 

0

0: 15 sec.

 

 

Maximum OGM recording time

0

1: 20 sec.

 

2

 

 

 

 

1

0: 30 sec.

 

 

 

 

 

 

 

 

 

 

1

1: 50 sec.

 

 

 

 

 

 

 

 

 

 

 

 

No. 3

4

 

 

3

 

Time length from CML ON to

0

0: 4 sec.

 

 

 

start of pseudo ring backtone

0

1: 3 sec.

 

 

4

 

 

 

 

transmission

1

0: 2 sec.

 

 

 

 

 

 

 

 

 

1

1: 1 sec.

 

5

 

 

0: 0 dB

1: 8 dB

 

Attenuator for playback of

0: 0 dB

1: 4 dB

 

 

ICM/OGM to the line

0: 0 dB

1: 2 dB

8

 

 

 

0: 0 dB

1: 1 dB

 

 

 

 

 

 

 

 

 

 

 

- Selectors 1 and 2: Maximum OGM recording time

These selectors set the allowable maximum recording time for an OGM.

- Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission

These selectors set the length of time from CML-ON up to the start of pseudo ring backtone transmission.

In models with OGM facilities, the settings made by these selectors also apply to the length of time from CML-ON up to the start of OGM transmission.

- Selectors 5 through 8: Attenuator for playback of ICM/OGM to the line

Setting two or more selectors to “1” produces addition of attenuation assigned to each selector.

This setting is not limited by selector 8 on WSW23.

App. 1-29

Confidential