(5)Turn the Panel unit upside down, and then disconnect the Connector (CN4) from the Panel PCB ASSY.

(6)Release the Lock and disconnect the Flat cable (CN3) from the Panel PCB ASSY.

Note:

-After disconnecting the flat cable(s), check that each cable is not damaged at its end or short-circuited.

-When connecting the flat cable(s), do not insert it at an angle. After insertion, check that the cable is not at an angle.

CN4

Panel PCB ASSY

CN3 (Flat cable)

CN3 (Flat cable)

Lock

Fig. 3-124

(7) Release the eight Hooks to remove the Panel PCB ASSY from the Panel unit.

Panel PCB ASSY

Hooks

Hooks

Hooks

Panel unit

Hooks

Fig. 3-125

3-101