Drum Error
Slide the Green tab on Drum Unit in each color. Refer to the User’s Guide for the procedures.
Dirt on drum unit
User Check
-Clean the corona wire in the drum unit.
-Replace the drum unit with a new one.
Step | Cause | Remedy |
1 | Dirt or dust on drum unit | Clean the electrodes on the drum unit. |
| electrodes | |
2 | Charge HVPS PCB failure | Replace the charge HVPS PCB ASSY. |
|
|
|
3 | Engine PCB failure | Replace the engine PCB ASSY. |
Error code 82
Calibrate
Calibration failed. Press start, and try again.
Density patch measurement is not completed normally when implementing calibration from the control panel.
User Check
-Check if there is a scratch, dirt or the like on the belt unit. If there is, replace the belt unit with a new one.
-Check if the genuine toner cartridges are installed in the correct order of colors.
Step | Cause | Remedy |
|
|
|
1 | Density sensor shutter not | Correct smooth operation of the density sensor |
| operating smoothly or | shutter. |
| catching in some position |
|
2 | Harness connection failure of | Check the harness connection of the density |
| density sensor holder ASSY | sensor holder ASSY and reconnect it. |
3 | Density sensor failure | Replace the density sensor holder ASSY. |
4 | Transfer HVPS PCB failure | Replace the transfer HVPS PCB ASSY. |
5 | Engine PCB failure | Replace the engine PCB ASSY. |
|
|
|