(3)Remove the two cup S M3x6 Taptite screws, and then remove the Transfer HVPS PCB unit.

<Back side>

Transfer HVPS PCB unit

Taptite, cup S M3x6

Taptite, cup S M3x6

Fig. 3-31

8.11Registration-mark Sensor PCB ASSY 1, 2/ Density Sensor/ Registration Relay PCB ASSY/ Transfer HVPS PCB ASSY

(1)Remove the bind B M3x8 Taptite screw, and then remove the Earth plate 3.

Taptite, bind B M3x8

Earth plate 3

Transfer HVPS PCB unit

Fig. 3-32

3-48

Confidential