< WSW57 >

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

 

No. 1

2

3

 

 

 

0

0

0: 0 V

 

1

 

0

0

1: 5 V (Default)

 

Caller ID judgment voltage

0

1

0: 10 V

 

(to be distinguished from rings)

0

1

1: 15 V

 

3

(Not used.)

1

0

0: 20 V

 

 

 

1

0

1: 25 V

 

 

 

1

1

0: 30 V

 

 

 

1

1

1: Max.

 

 

 

 

 

 

 

 

 

No. 4

5

6

 

 

 

0

0

0: 0 V

 

4

Caller ID judgment voltage

0

0

1: 5 V (Default)

 

0

1

0: 10 V

 

(to be distinguished from

0

1

1: 15 V

 

reverse polarity voltages)

 

 

1

0

0: 20 V

 

6

(Not used.)

 

 

 

1

0

1: 25 V

 

 

 

1

1

0: 30 V

 

 

 

1

1

1: Max.

 

 

 

 

 

 

 

7

Not used.

 

 

 

 

 

 

 

 

 

 

8

Base unit start button after

0: Invalid (Default)

1: Valid

cordless handset dialing

 

 

 

 

 

 

 

 

 

 

 

Note:

Selectors 1 through 6 are applicable only to models designed for the European market.

-Selectors 1 through 3: Caller ID judgment voltage (to be distinguished from rings) (Not used.)

If caller IDs cannot be displayed because of confusion with rings due to variations in the voltage, increase the judgment voltage.

However, do make sure that the voltage value set by selectors 1 through 3 of this switch is equal to, or greater than, the value set by selectors 4 through 6 of the same switch.

-Selectors 4 through 6: Caller ID judgment voltage (to be distinguished from reverse polarity voltages) (Not used.)

If caller IDs cannot be displayed because reverse polarities cannot be detected due to a large difference between line voltages in a reverse polarity condition and in a steady condition, increase the judgment voltage.

However, do make sure that the voltage value set by selectors 1 through 3 of this switch is equal to, or greater than, the value set by selectors 4 through 6 of the same switch.

- Selector 8: Base unit start button after cordless handset dialing

Even if the base unit start button is pressed to start a FAX transmission during calling when this selector is in its default state, no FAX transmission will occur. By using this selector, it is possible to make the base unit start button operative after cordless handset dialing.

App. 1-61

Confidential