Since print density is likely to become darker as the toner gets older, the developing bias is lowered by degrees (bias voltage is reduced) according to the number of develop roller rotations so that an almost fixed density can be maintained from the beginning to the end. The developing bias voltage can be verified in the display of log information (Function code 80).
In the case that the toner cartridge is replaced with a new one, the develop roller counter and developing bias voltage are reset at the same time. This function allows you to reset these manually.
Panel Operation | Function |
Pressing the Clear/Back button while the front | Menus of the develop roller counter reset |
cover is being opened. |
|
<Operating Procedure>
(1)Press the Clear/Back button while the front cover is being opened.
(2)The “Reset Menu” appears on the LCD. Press the or
buttons to select the appropriate toner cartrige, and then press the OK button.
LCD | Description |
Reset the develop roller counter of standard black | |
| toner cartridge. |
Reset the develop roller counter of | |
| black toner cartridge. |
Reset the develop roller counter of standard cyan | |
| toner cartridge. |
Reset the develop roller counter of | |
| cyan toner cartridge. |
Reset the develop roller counter of standard | |
| magenta toner cartridge. |
Reset the develop roller counter of | |
| magenta toner cartridge. |
Reset the develop roller counter of standard yellow | |
| toner cartridge. |
Reset the develop roller counter of | |
| yellow toner cartridge. |
(3) The
(4) The counter is reset when pressing the 1 button.
(5)The machine returns to the status that the front cover is opened.
Note:
If there is no operation for 60 seconds or more, the machine automatically returns to step (1).