7.TROUBLESHOOTING OF THE COMMUNICATIONS ERRORS
If a communications error occurs, the facsimile equipment
(1)Gives the alarm (intermittent bleep) for approximately four seconds.
(2)Indicates the appropriate error message on the LCD.
(3)Prints the transmission report during fax transmission.
Definition of error codes on the communications list
(1) | Calling |
|
|
|
|
|
|
| Code 1 | Code 2 | Causes |
|
|
|
|
| 10 | 08 | Wrong number called. |
|
|
|
|
| 11 | 01 | No dial tone detected before start of dialing. |
| 11 | 02 | Busy tone detected before dialing. |
|
|
|
|
| 11 | 03 | 2nd dial tone not detected. |
| 11 | 05 | No loop current detected. * |
| 11 | 06 | Busy tone detected after dialing or called. |
|
|
|
|
| 11 | 07 | No response from the remote station in sending. |
|
|
|
|
| 11 | 10 | Unobtainable tone detected after dialing. |
|
|
|
|
|
|
|
|
| 17 | 07 | No response from the calling station in receiving. |
|
|
|
|
|
|
|
|
|
|
| * Available in German models only. |
(2) | Command reception |
| |
|
|
|
|
| Code 1 | Code 2 | Causes |
|
|
|
|
| 20 | 01 | Unable to detect a flag field. |
| 20 | 02 | Carrier was OFF for 200 ms or longer. |
|
|
|
|
| 20 | 03 | Abort detected (“1” in succession for 7 bits or more). |
|
|
|
|
| 20 | 04 | Overrun detected. |
|
|
|
|
| 20 | 05 | A frame for 3 seconds or more received. |
| 20 | 06 | CRC error in answerback. |
|
|
|
|
| 20 | 07 | Error command received. |
|
|
|
|
| 20 | 08 | Invalid command received. |
| 20 | 09 | Command ignored once for document setting or for dumping- |
|
|
| out at |
| 20 | 0A | T5 |
|
|
|
|
| 20 | 0B | CRP received. |
|
|
|
|
| 20 | 0C | EOR and NULL received. |
|
|
|
|
| 20 | 0C | EOR received. |
|
|
|
|