8.18Pull arm L, R/ Hinge Protection Cover ASSY

(1)Disconnect the three Connectors (CN14, CN16, CN21) from the Main PCB ASSY.

(2)Disconnect the Flat cable (CN17) from the Main PCB ASSY, and then pull out the Flat cable from the Core.

Note:

-After disconnecting the flat cable(s), check that each cable is not damaged at its end or short-circuited.

-When connecting the flat cable(s), do not insert it at an angle. After insertion, check that the cable is not at an angle.

Document scanner unit ASSY

Core

Main PCB ASSY

Flat cable (CN17)

CN16

CN14

 

<Left side>

CN21

 

Fig. 3-52

(3)Remove the three cup B M4x12 Taptite screws, and then remove the Hinge protection cover ASSY.

Document scanner unit ASSY

Hinge protection cover ASSY

<Back side>

Taptite, cup B M4x12

Fig. 3-53

3-61

Confidential