<Function>
This function makes the
| LCD | Description | |
| REGI_SENS ADJUST | Adjust the sensitivity of the | |
1 | BELT OFF | belt unit is not operated. This is to check whether the | |
| |||
|
| ||
| REGI_SENS ADJUST | Adjust the sensitivity of the | |
2 | BELT ON | belt unit is operated. (This adjustment is the same as the | |
| operation before the color registration.) | ||
|
| ||
3 | REGI_SENS ADJUST | Check whether there is no scratch on the surface of the belt | |
BELT CHECK | unit within the detectable range of | ||
| |||
|
| ||
|
|
|
<Operating Procedure>
(1)Press the 7 and 5 buttons in this order in the initial stage of the maintenance mode. “REGI SENS ADJUST” appears on the LCD.
(2)Press the or button to select the appropriate term.
(3)Press the OK button so that the selected operation is carried out.
Note:
-If you press the OK button during the sensitivity adjustment or after the error message appears on the LCD, the sensitivity adjustment is started again.
-In the case that the error occurs, refer to the next page to check the error description and the way to solve it.
(4)Upon completion of the above operation, the machine beeps for one second and returns to the initial stage of the maintenance mode.
Confidential |