(8) Remove the Edge actuator and PE actuator, and remove the Edge actuator spring.

Edge actuator spring

Edge actuator

 

PE actuator

Paper feed frame

<Upper side>

Fig. 3-178

(9) Release the three Hooks to remove the T1 PE/edge sensor PCB ASSY.

T1 PE/edge sensor PCB ASSY

Hook

Hook

<Upper side>

Hook

Fig. 3-179

3-130