- Selectors 5 and 6: Busy tone detection in automatic sending mode

These selectors determine whether or not the machine automatically disconnects a line upon detection of a busy tone in automatic sending mode.

Setting selector 6 to “0” ignores a busy tone so that the machine does not disconnect the line. Setting selectors 5 and 6 to “0” and “1,” respectively, makes the machine detect a busy tone only after dialing and disconnect the line.

Setting both of selectors 5 and 6 to “1” makes the machine detect a busy tone before and after dialing and then disconnect the line.

- Selector 7: Busy tone detection in automatic receiving mode

This selector determines whether or not the machine automatically disconnects the line upon detection of a busy tone in automatic receiving mode.

< WSW06 >

 

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

 

 

 

 

 

No. 1

2

3

 

 

 

 

 

0

0

0: No pause

 

 

 

 

0

0

1: 3.5 sec. wait

 

 

 

 

0

1

0: 7 sec. wait

 

 

 

 

0

1

1: 10.5 sec. wait

 

1

 

Redial/Pause button setting

1

0

0: 2.8 sec. wait

 

 

1

0

1: 2nd dial tone detection

 

 

and 2nd dial tone detection

 

 

 

both in DP and push-

 

 

 

 

 

 

 

3

 

 

 

 

 

button (PB) dialing system

 

 

 

 

1

1

0: 2nd dial tone detection

 

 

 

 

 

 

 

only in pulse dialing (DP)

 

 

 

 

 

 

 

system

 

 

 

 

1

1

1: 2nd dial tone detection

 

 

 

 

 

 

 

both in DP and push-

 

 

 

 

 

 

 

button (PB) dialing system

 

 

 

 

No. 4

5

6

 

 

 

 

 

0

0

0: 50 ms

 

4

 

 

0

0

1: 250 ms

 

 

 

0

1

0: 500 ms

 

 

Detection of international tone

0

1

1: 620 ms

 

6

 

 

1

0

0: 800 ms

 

 

 

 

1

0

1: 1.5 sec.

 

 

 

 

1

1

0: 2.0 sec.

 

 

 

 

1

1

1: 2.5 sec.

 

 

 

 

 

 

 

 

 

7

 

No. of 2nd dial tone detection

0: 1 cycle

1: 2 cycles

 

 

cycles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Allowable instantaneous

 

 

 

 

 

8

 

interrupt during reception of 2nd

0: 30 ms

1: 50 ms

 

 

 

dial tone

 

 

 

 

 

 

 

 

 

 

 

 

Note:

Selectors 4 through 8 are not applicable in those countries where no dial tone detection is supported, e.g., U.S.A.

App. 1-10

Confidential